top of page

Los Angeles County Sanitation Districts

Los Angeles County Exploring Tulare Lake Compost System Solutions


Los Angeles County needed a composting system for Tulare Lake that met or surpassed emission requirements from the San Joaquin Valley Air Pollution Control District in California.



PROJECT DETAILS


Ownership: Los Angeles County Sanitation Districts

Location: Kettleman City, CA

Start-Up: 2016

Product: SG HEAP® System with GORE® Cover

Input quantity: 200,000 TPY Stage 1 / Final Design Capacity: 1,000,000 TPY

No. of Heaps: 72 Heaps, 54 covered, 164 ft. x 26 ft. x 12 ft. each

Treatment Time: 8 weeks in 3 Phases

Aeration: In-floor

Control Parameters: Oxygen Control Mode

Input material: Biosolids / Wood Chips / Grass & Straw / Yard Waste

Equipment: Maintenance Building / Front-end-loaders / Conveyors / Stationary Mixers / Screen

End Product: High Quality Finished Compost



THE SG SOLUTION

Systematically Demonstrating Performance and Compliance


Of significant importance to the LACSD project was the SG HEAP® System with GORE® Covers’ ability to comply with the state and local regulatory requirements for meeting a Class A biosolids compost and for VOC emissions reduction.


The SG solution provided cost saving benefits in both design and operation as compared to the original negative aerated static pile (ASP) design with a biofilter. And, the solution allowed for a phased in construction approach due SG’s modular design and flexibility to expand as the process capacity grows over time.


As part of the technology selection process, the team participated in a series of demonstrations using the SG MOBILE® System with GORE® Covers and then the subsequent review by regulators to demonstrate the system’s performance and compliance with strict rules governing pathogen reduction and VOC emission control. As a direct result of these trials, and combined with existing data from other GORE® Cover operating facilities, the GORE® Cover technology has received an assessment and recognition from the San Joaquin Valley Air Pollution Control District in California.



PROJECT GALLERY

The SG HEAP® Systems at Los Angeles County Sanitation District




RESULTS DELIVERED

Receiving the Right Recommendations


San Joaquin Valley Air Pollution Control District concurs that the GORE® Cover technology, when properly installed, operated and maintained per GORE specifications, is capable of meeting and/or exceeding the VOC emission requirements of District Rule 4565 (Biosolids, Animal Manure, and Poultry Litter Operations), District Rule 4566 (Organic Material Composting Operations) and District Best Available Control Technology (BACT) for co-composting operations.


Facilities using the GORE® Cover experience greater than 90% reduction in process odors and VOC emissions when compared to open and uncovered compost systems.


The GORE® Cover technology also received a recommendation of national equivalency from the EPA Pathogen Equivalency Committee (PEC) that the GORE® Cover is capable of meeting and/or exceeding criteria for achieving Class A Biosolids as described in Alternative 5: Use of PFRP [503.32(a) (7) and (B) (1) of Appendix B. in a covered aerated static pile without the use of a insulating layer of material (such as finished compost).


At full design capacity, this facility will be capable of processing upwards of 1,000,000 TPY of organic material, or 500,000 wet tons of biosolids mixed with 500,000 tons of wood based bulking material.



DOWNLOAD FULL PROJECT PROFILE BELOW

lacsd-project-profile_2019
.pdf
Download PDF • 621KB



bottom of page